Specification
[1] study of typical air conditioning system
with open air duct, air cooler, steam humidifier, fan, air preheaters and reheaters
[2] determination of the air flow rate by differential pressure measurement
[3] combined sensors for the air humidity and temperature before and after each stage, sensor, pressure sensor and on/off switch
[4] data acquisition software with PC
Technical Data
Steam humidifier power consumption: 4…6kW
– steam capacity: 5…6kg/h, switchable in three stages Fan
– air flow rate: 1000…1200m3/h
Condensor
• power consumption: 1…1.25kW
• refrigeration capacity: 2…2.5kW
Air preheater: 1…1.5kW, switchable in two stages Air reheater: 1.5…2.5kW, switchable in two stages
Air duct approx., WxH: 300x300mm
evaporator as air cooler: 5.5…6.5kW
Refrigerant: R513A/R134a; filling volume: 3…3.5kg
– temperature: -100…200°C – humidity: 10…90%
Reviews