Uncategorized – Impact https://impactgroupcous.com Impact Group Co.Us LLC Mon, 18 Dec 2023 13:11:42 +0000 en-US hourly 1 https://wordpress.org/?v=6.5.5 IM231211S75 Swivel Chair Seat https://impactgroupcous.com/product/im231211s75-swivel-chair-seat/ https://impactgroupcous.com/product/im231211s75-swivel-chair-seat/#respond Mon, 18 Dec 2023 13:09:34 +0000 https://impactgroupcous.com/?post_type=product&p=3160

Specification
[1] student swivel seat chair
[2] comfortable when sitting for along time [3] comfortable for laboratory teaching Technical data
Variable seat height 380….550mm Smooth gas operating lift
Color black
Seat diameter approx. 40mm
Weight capacity approx. 100kg

]]>
https://impactgroupcous.com/product/im231211s75-swivel-chair-seat/feed/ 0
IM231211S74 Compressed Air Generation Plant with Piston Compressor https://impactgroupcous.com/product/im231211s74-compressed-air-generation-plant-with-piston-compressor/ https://impactgroupcous.com/product/im231211s74-compressed-air-generation-plant-with-piston-compressor/#respond Mon, 18 Dec 2023 13:08:59 +0000 https://impactgroupcous.com/?post_type=product&p=3159

Specification
[1] investigation of of a single-stage air compressor, Calculation of power, efficiency, work

[2] pressure vessel with manometer, safety valve, valve for drainage and connection for consumers [4] digital display to show voltage, current, effective power
Technical data
Piston compressor

• delivery pressure: 8…18bar with 105…170L/min • bore: 45…70mm
• stroke: 35…50mm
Drive motor

• power consumption: 0.7…1.5kW Pressure vessel
• content: 12…25L
•pressure: 9.5…20bar

]]>
https://impactgroupcous.com/product/im231211s74-compressed-air-generation-plant-with-piston-compressor/feed/ 0
IM231211S73 PV Solar Module Measurements https://impactgroupcous.com/product/im231211s73-pv-solar-module-measurements/ https://impactgroupcous.com/product/im231211s73-pv-solar-module-measurements/#respond Mon, 18 Dec 2023 13:07:20 +0000 https://impactgroupcous.com/?post_type=product&p=3158

Specification
[1]study of solar module measurements, series and parallel installation [2] slide resistor as variable load

[3] measuring amplifier with digital displays for current, voltage, illuminance and module temperature [4] reference cell as illuminance sensor
Technical data
Module design number of cells: 36

• cell material: monocrystalline silicon, approx. module area: 0.64m2 Typical module parameters under STC, output: 85…100W
• short-circuit current: approx. 5.3A
• open-circuit voltage: approx. 22V

two Invertor: AC to DC/ DC to AC, >90watt, 220v single phase
Two charge Controller: 12/24v
four Rechargable solar battery: 12v/1000AH/10HR
Include other system components like socket (male and female), switch, solar electric cable and connectors, etc.

]]>
https://impactgroupcous.com/product/im231211s73-pv-solar-module-measurements/feed/ 0
IM231211S72 Solar Water Heating with Flat Plate Collector https://impactgroupcous.com/product/im231211s72-solar-water-heating-with-flat-plate-collector/ https://impactgroupcous.com/product/im231211s72-solar-water-heating-with-flat-plate-collector/#respond Mon, 18 Dec 2023 13:06:45 +0000 https://impactgroupcous.com/?post_type=product&p=3157

Specification
[1] study of the function and operating behaviour of a solar thermal flat collector operation with solar radiation
[2] tracking angle and bimetallic thermometers
[3] solar circuit with collector, pump, expansion vessel and safety valve
[4] hot water circuit with buffer tank, pump and plate heat exchanger

[5] solar controller with temperature, flow rate and illuminance sensors [6] data logger with SD memory card and PC
Technical data
Solar circuit collector

· absorbing surface: 2…3m2
· flow rate: 20…200L/h
· operating pressure: 1…3bar with safety valve: 4…7bar Hot water circuit
• plate heat exchanger: 2.75…3.5kW, 10 plates
• tank 65…75L

]]>
https://impactgroupcous.com/product/im231211s72-solar-water-heating-with-flat-plate-collector/feed/ 0
IM231211S71 Circulating Pumps Training Panel https://impactgroupcous.com/product/im231211s71-circulating-pumps-training-panel/ https://impactgroupcous.com/product/im231211s71-circulating-pumps-training-panel/#respond Mon, 18 Dec 2023 13:06:18 +0000 https://impactgroupcous.com/?post_type=product&p=3156

Specification
[1] study of Series and parallel operation of 2 pumps
[2] Training panel can be changed to various operating modes using ball valves
[3] Pressure measurement with 6 Bourdon tube manometers, 1 bimetallic dial thermometer and 2 rotameters
Technical Data
2 circulating pumps power consumption: 70…80W
– approx. flow rate: 55…70L/min with head: 4…5m

 

]]>
https://impactgroupcous.com/product/im231211s71-circulating-pumps-training-panel/feed/ 0
IM231211S70 Temperature Measurement Training Panel https://impactgroupcous.com/product/im231211s70-temperature-measurement-training-panel/ https://impactgroupcous.com/product/im231211s70-temperature-measurement-training-panel/#respond Mon, 18 Dec 2023 13:05:42 +0000 https://impactgroupcous.com/?post_type=product&p=3155

[1] study of 4 different temperature measuring techniques
[2] 2 Digital display of the temperatures measured using sensors and flow rate measurement with rotameter
Technical Data
Rotameter measuring ranges: 150…1650L/h
Thermometer
– bimetallic dial thermometer: 0…100°C

– liquid expansion thermometer: 0…80°C
– resistance thermometer: -50…450°C
– thermocouple type K: 0…1200°C
water connection, hot water supply: 1350….1700L/h

]]>
https://impactgroupcous.com/product/im231211s70-temperature-measurement-training-panel/feed/ 0
IM231211S69 Heat Exchanger Supply Unit https://impactgroupcous.com/product/im231211s69-heat-exchanger-supply-unit/ https://impactgroupcous.com/product/im231211s69-heat-exchanger-supply-unit/#respond Mon, 18 Dec 2023 13:03:43 +0000 https://impactgroupcous.com/?post_type=product&p=3136

Specification

  • ⦁  Demonstration of heat transfer and comparison of a types of heat exchangers.
  • ⦁  Determination of the overall heat transfer coefficient, Calculation of energy balance, heat loss, mean temperature difference and effectiveness
    Technical Data

⦁ Electrical heater power 2…5 kW

Pump flow rate: above 10 L /min, head 3.5…7m ⦁ Power consumption: 170…2000W

  • ⦁  Hot water temperature: 50…100oC.
  • ⦁  The unit is supplied with an electronic and computerized monitoring system, including computer.
]]>
https://impactgroupcous.com/product/im231211s69-heat-exchanger-supply-unit/feed/ 0
IM231211S68 Control Unit for Ventilation System https://impactgroupcous.com/product/im231211s68-control-unit-for-ventilation-system/ https://impactgroupcous.com/product/im231211s68-control-unit-for-ventilation-system/#respond Mon, 18 Dec 2023 13:02:55 +0000 https://impactgroupcous.com/?post_type=product&p=3135

Specification
[1]study of ventilation system using electronic controller with temperature sensor with display and circulating pump

[2] cold and hot water supply quick-release couplings

Technical Data
Pump
– approx. flow rate: 55…70L/min; head: 4…5m – temperature measuring range: -50…600°C
– 3-way mixing valve diameter: 18…22mm water drain: 1.75…2.5m3/h

]]>
https://impactgroupcous.com/product/im231211s68-control-unit-for-ventilation-system/feed/ 0
IM231211S67 Ventilation System https://impactgroupcous.com/product/im231211s67-ventilation-system/ https://impactgroupcous.com/product/im231211s67-ventilation-system/#respond Mon, 18 Dec 2023 13:02:23 +0000 https://impactgroupcous.com/?post_type=product&p=3134

Specification
[1] investigation the flow rate via differential pressure
[2] study of operation of a ventilation system and components: heat exchanger to heat/cool the air, 3 sound insulation links
[3] protective grating and adjustable multi-leaf damper at the air inlet with air filter
[4] various air outlets for air distribution in the room: disc valve, ceiling vent and ventilation grill with adjustable flow rate

[5] study of fire protection flap prevents the cross-over of fire and smoke in the air duct Technical Data
Power consubtion: 1….1.3kW
Air duct: 2 parts with WxH 612x409mm and 710x304mm Ventilator

• flow rate:2000… 2500m3/h
• pressure: -1…25mbar
drain, cold and hot water connection

]]>
https://impactgroupcous.com/product/im231211s67-ventilation-system/feed/ 0
IM231211S66 Efficiency in Heating Technology https://impactgroupcous.com/product/im231211s66-efficiency-in-heating-technology/ https://impactgroupcous.com/product/im231211s66-efficiency-in-heating-technology/#respond Mon, 18 Dec 2023 13:01:53 +0000 https://impactgroupcous.com/?post_type=product&p=3133

Specification
[1] fundamentals of energy efficient heating technology
[2] closed water circuit with 2 circulating pumps, expansion vessel, heater and convector, 7 differential pressure sensors, 4 temperature sensors, 1 effective power sensor and 1 flow rate sensor
[3] data acquisition software with PC
Technical Data

Conventional circulating pump
– power consumption: 130…150W; approx. flow rate: 4.5…5.5m3/h with Differential pressure-controlled circulating pump
– flow rate:2… 3.5m3/h; head: 6…8m
– Electric heater: 1750…2500W
– Expansion vessel: 1.5…2.5L
Software controller temperature: 0…100°C

]]>
https://impactgroupcous.com/product/im231211s66-efficiency-in-heating-technology/feed/ 0