DETERMINATION OF THE VOIDS CONTENT OF DRY COMPACTED FILLER
The apparatus consists of:
- cylinder having inside diameter 25.4 mm;
- plunger freely sliding into the cylinder with max. lateral play of 0.20 ± 0.05 mm;
- four columns and metallic base holding the whole.
To perform the test a measuring device (vernier caliper with 0.01 mm accuracy) is required: see accessory.
Weight: 4 kg